Power Settings, Wattages, and Environmental Requirements
Topic
This article explains the power (in watts) used by each Datto backup appliance model and provides their environmental requirements.
Environment
- Datto SIRIS
- Datto ALTO
- Datto NAS
Description
SIRIS 5 and ALTO 4
The latest generation SIRIS and ALTO models are based on DELL hardware. You can find detailed information on these models based on the specifications provided by DELL.
SIRIS 5 Model | DELL Chassis |
---|---|
ALTO 4 | DELL OptiPlex 3080, Datto-S4X chassis |
S5X | |
S5-2, 3, or 4 | |
S5-6 to 36 | |
To determine the chassis model refer to Updating SIRIS 5 and ALTO 4 firmware.
Legacy Models
Device Model | Chassis Style | Power Supply Wattage | Input Voltage | Efficiency | Input Current | Estimated BTU Output |
---|---|---|---|---|---|---|
6TB Node 10TB Node 20TB Node | 2U Rackmount Supermicro 826 | 920 Watts Dual | 100-240 V | 11 Amps @ 100V 4.4 Amps @ 240V | About 3,400 BTU/hr | |
ALTO ALTO 2 S3X1 S3X1 | Zotac MiniPC | 65 Watts | 100-240 V | About 1.5 Amps | ||
S250 S500 S1000 | Micro ATX Tower InWin BL634 | 300 Watts | 115-230 V | 7 Amps @ 115V 4 Amps @ 230V | About 1,460 BTU/hr | |
S2000 S3000 | 2U Rackmount SuperMicro 822 | 400 Watts | 100-240V | 6 Amps @ 100V 2.7 Amps @ 240V | About 1,660 BTU/hr | |
S5000 S10000 S20000 | 2U Rackmount Supermicro 826 | 920 Watts Dual | 100-240V | 11 Amps @ 100V 4.4 Amps @ 240V | About 3,400 BTU/hr | |
S40000 N64,000 N96,000 S3E100,000 S3E120,000 | 4U Rackmount Supermicro 847 | 1400 Watts
Dual | 100-240V | 80 Plus Gold 90.9% | 13 Amps @ 100V 5.7 Amps @ 240V | About 5,300 BTU/hr |
SL250 SL500 SL1000 | Mini ITX Tower InWin BM639 | 160 Watts | 100-240 V | 4 Amps | About 780 BTU/hr | |
S4B1 S4B2 S4B3 S4B4 | XEO-96-Desktop | 250 -Watts | 120-240V | |||
SB500 SB1000 SB2000 | 4 Bay Tower UNAS NSC-400-BK | 250 Watts | 100-240 V | 80 Plus Bronze 82% | About 850 BTU/hr | |
SP1000 SP2000 SP3000 SP5000 | 2U Rackmount Supermicro 825 | 560 Watts | 100-240 V | 80 Plus Gold 89% | 7.5 Amps @ 100V 4.2 Amps @ 240V | About 1910 BTU/hr |
SP Tower | 4U Tower Supermicro 743T | 500 Watts | 100-240 V | 80 Plus Bronze 84% | 7 Amps @ 100V 3.5 Amps @ 240V | |
SE5,000 SE10,000 SE20,000 SE36,000 | 2U Rackmount Supermicro 826 | 920 Watts
Dual | 100-240 V | 80 Plus Platinum 93% | 10.7 Amps @ 100V 4.2 Amps @ 240V | About 3140 BTU/hr |
SE40,000 SE50,000 SE60,000 S3E60,000 S3E80,000 | 4U Rackmount Supermicro 846 | 1280 Watts
Dual | 100-240 V | 80 Plus Platinum 94% | 12 Amps @ 100V 6 Amps @ 240V | |
AXL1000 AXL2000 AXL3000 | 4 Bay Tower UNAS NSC-400-BL | 250 Watts | 100-240 V | 80 Plus Bronze 82% | About 850 BTU/hr | |
AXL6000 AXL10000 AXL24000 | 8 Bay Tower UNAS NSC-800-BL | 360 Watts | 100-240 V | 6 Amps @ 100V 2.7 Amps @ 240V | About 1230 BTU/hr | |
DN500 DN1000 DN2000 DN3000 | 4 Bay Tower UNAS NSC-400-BK | 250 Watts | 100-240 V | 80 Plus Bronze 82% | About 850 BTU/hr | |
DN6000 DN10000 DN24000 | 8 Bay Tower UNAS NSC-800-BK | 360 Watts | 100-240 V | 6 Amps @ 100V 2.7 Amps @ 240V | About 1230 BTU/hr | |
DN30,000 DN40,000 | 2U Rackmount Supermicro 826 | 920 Watts
Dual | 100-240 V | 80 Plus Platinum 93% | 10.7 Amps @ 100V 4.2 Amps @ 240V | About 3140 BTU/hr |
DN50,000 DN60,000 | 4U Rackmount Supermicro 846 | 1280 Watts
Dual | 100-240 V | 80 Plus Platinum 94% | 12 Amps @ 100V 6 Amps @ 240V | |
S3B500 S3B1000 S3B2000 S3B3000 | 4 Bay Tower UNAS NSC-400-BK | 250 Watts | 100-240 V | 80 Plus Bronze 82% | About 850 BTU/hr | |
S4P2 S4P4 S4P6 S4P10 S3P1000 S3P2000 S3P4000 S3P6000 S3P10000 | 1U Rackmount Chenbro RM14604 | 400 Watts | 100-240 V | 80 Plus Gold | 6 Amps @ 100V 3 Amps @ 240V | About 1010 BTU/hr |
S4E6 S4E12 S4E18 S4E24 S4E36 S4E48 S4E60 S4E80 S4E100 S3E6,000 S3E12,000 S3E18,000 S3E24,000 S3E36,000 S3E48,000 N3E20,000 N3E40,000 | 2U Rackmount Chenbro RM238 (S4) Chenbro RM237(S3) | 800 Watts
Dual | 100-240 V | 10 Amps @ 100V 5 Amps @ 240V | About 2200 BTU/hr | |
N3E80,000 N3E120,000 | 4U Rackmount Chenbro RM417 | 800 Watts
Dual | 100-240 V | 80 Plus Gold | 10 Amps @ 100V 7 Amps @ 240V | About 2200 BTU/hr |
SL2000 SL3000 | Micro ATX Tower InWin BL634 | 300 Watts | 115-230 V | About 1.5 Amps | ||
SL/GX 2000 SL3000 | 2U Rackmount SuperMicro 822 | 400 Watts | 100-240V | 6 Amps @ 100V 2.7 Amps @ 240V | About 1,660 BTU/hr | |
SL5000 SL10000 | 2U Rackmount SuperMicro 822 | 400 Watts | 100-240V | 6 Amps @ 100V 2.7 Amps @ 240V | About 1,660 BTU/hr |
Details
For non-Dell models, the only power option located in the BIOS is Restore after AC loss (or a similarly-named feature). Setting this option to Last State or Memory ensures that the device will automatically power on and resume operation following a power outage.
Dell chassis models have an increased option set. Please review the manufacturer’s documentation (provided in the Siris 5 table above) for a full list of features.
Power supply units in the UNAS Tower chassis or any of the rackmount chassis will automatically detect the proper input voltage.
In SIRIS devices that have dual PSUs, both must be operational and in good working order for the SIRIS device to perform properly.
Environmental Requirements
All units listed in this article have the following temperature and humidity requirements:
- Environmental temperature: 5°C ~ 35°C (41°F ~ 95°F)
- Environmental humidity: 10% ~ 85% (non-condensing)
Power Draws
Datto appliances have an average load of 40% to 80% on the PSU, so the power draw for each device is less than the wattage of the power supply.
- Rackmounts use approximately 40% to 60% of the PSU.
- Towers use approximately 70% to 80% of the PSU.
Datto recommends connecting your backup appliance to a battery backup (also known as an Uninterruptible Power Supply or UPS) to ensure consistent operation during low voltage and brownout conditions. The rated wattage of your UPS should at a minimum, match the wattage of your power supply.